Differential pressure rise event for filters of HTTR primary helium gas circulators, 1; Investigation of differential pressure rise event

Nemoto, Takahiro; Arakawa, Ryoki; Kawakami, Satoru; Nagasumi, Satoru; Yokoyama, Keisuke; Watanabe, Masashi; Onishi, Takashi; Kawamoto, Taiki; Furusawa, Takayuki; Inoi, Hiroyuki; et al.

JAEA-Technology 2023-005, 33 Pages, 2023/05

JAEA-Technology-2023-005.pdf:5.25MB

During shut down of the HTTR (High Temperature engineering Test Reactor) RS-14 cycle, an increasing trend of filter differential pressure for the helium gas circulator was observed. In order to investigate this phenomenon, the blower of the primary helium purification system was disassembled and inspected. As a result, it is clear that the silicon oil mist entered into the primary coolant due to the deterioration of the charcoal filter performance. The replacement and further investigation of the filter are planning to prevent the reoccurrence of the same phenomenon in the future.

JAEA Reports

Replacement of the filter for primary helium circulators of the HTTR

Furusawa, Takayuki; Sumita, Junya; Ueta, Shohei; Nemoto, Takahiro; Oyama, Sunao*; Kamata, Takashi

JAERI-Tech 2004-024, 46 Pages, 2004/03

JAERI-Tech-2004-024.pdf:6.75MB

Primary helium circulators of the HTTR are the important component as the helium gas which is reactor coolant, and three circulators for the primary pressurized water cooler and one for the intermediate heat exchanger are installed in primary cooling system. In the upstream of these circulators, the filter has been installed in order to suppress that it is entrapped in the bearing in which fine particles in helium gas, support main shaft of the helium circulator. The differential pressure of this filter rose gradually during rise-to-power test. The rise of the filter differential pressure of the helium circulator may cause the problem for reactor operation. Therefore, the filters were newly manufactured, and replacement of the filter was carried out. In replacement of the filter, appearance confirmation was carried out and deposit of the filter was analyzed. This paper described replacement of the filter and filter differential pressure rise investigation of the causes.